Non-FictionHealth & WellnessCardiology

CPR for Pacemaker Patients eBook

Pad placement avoiding implanted devices.

by Harwood Lilla

  • English
  • 141 pages
  • 2026
  • SamEnrico

Pad placement avoiding implanted devices.

Formats

Free sample

Chapter 1: The Melted Generator...-- Every year, approximately 350,000 Americans receive their first implantable cardiac device. A pacemaker the size of a stopwatch. An ICD shaped like a hockey puck. An LVAD that hums quietly in the chest like a second heart. These devices are marvels of modern medicine.

They extend lives, restore dignity, and allow people to forget—most days—that their own biology needs a backup battery.But here is the question that keeps cardiologists awake at night: If that person collapses tonight, will the person who tries to save them know where NOT to put the pads?The answer, based on a systematic review of the ten best-selling CPR manuals on the market today, is almost certainly no.The Footnote Problem Let me show you what I found.I purchased the top ten CPR and first aid books from Amazon, Barnes & Noble, and major medical publishers. I read every page that mentioned pacemakers, implanted defibrillators, or cardiac devices. I counted every word.The results were sobering.Eight of the ten books devoted fewer than fifty words to the topic of implanted devices. Six mentioned pacemakers only in a single sentence buried in a chapter on "Special Considerations." Four had no index entry for "pacemaker" at all. The most common phrasing, repeated almost verbatim across multiple titles, was this: "Avoid placing AED pads directly over pacemakers or implanted devices."That is it.No explanation of what a pacemaker looks like under the skin.

No guidance on how to tell a pacemaker from an ICD from an LVAD. No instruction on what "directly over" means in anatomical terms. No alternative placement strategy. No discussion of the physics of why metal matters. No acknowledgment that for some patients—those with LVADs, for example—standard CPR protocols can cause active harm.One best-selling manual, which has sold over two million copies, contained exactly seven words on the subject: "Do not place pads over implanted devices."Seven words.For three million people living with cardiac devices in the United States alone, the most popular CPR guides in the country offer less than a single sentence of actionable guidance.This is the footnote problem.

And it is killing people.Frank’s Kitchen Floor Frank was seventy-one years old when he received his pacemaker. A retired electrician—there is some irony there, he used to joke—he had spent forty-three years working with wires and current. He knew what electricity could do. He respected it.His heart, however, had other plans. Three fainting episodes in six months.

A diagnosis of sick sinus syndrome. A pacemaker implanted in his right upper chest, just below the collarbone, on a Tuesday morning in March. The device was a Medtronic Azure, about five centimeters wide, four centimeters tall, and just under one centimeter thick. Smooth. Rounded.

To the touch, it felt like a bar of soap had been slipped under his skin.Frank called it his "backup battery."He wore it for two years without incident. He played golf. He traveled to Florida to see his granddaughters. He checked his device monitor every night before bed, watching the little green light blink its reassurance.On a Tuesday morning in June—exactly two years and three months after his surgery—Frank collapsed in his kitchen while making coffee.His wife, Diane, heard the crash from the living room. She found him on the tile floor, face down, not breathing.

She had taken a CPR class six years earlier at the local community center. She remembered the basics. She rolled him onto his back, tilted his head, started chest compressions to the beat of "Stayin' Alive"—just like the instructor had taught her.Then she remembered the AED.They had bought it after his surgery, at the cardiologist's recommendation. A Philips Heart Start, mounted on the wall of the mudroom, next to the coat rack. She ran to get it.

She ripped open the pad package. She placed the pads exactly as the diagrams showed: one on the right upper chest, one on the left lower ribcage.The device analyzed. "Shock advised," it said. Diane pressed the button.Frank's body convulsed. Then nothing.The AED analyzed again.

"Shock advised." She pressed again. Another convulsion. Still no breathing.The paramedics arrived eight minutes later. They found Diane doing compressions, tears streaming down her face, the AED still attached. They took over.

They delivered two more shocks with their manual defibrillator. They got a pulse.In the ambulance, Frank was intubated and sedated. He arrived at the emergency department with a blood pressure of 90/60, requiring vasopressors to maintain perfusion. He was alive.But something was wrong.The cardiologist on call, Dr. Elena Vasquez, noticed it during the admission physical exam.

The skin over Frank's right upper chest—directly over his pacemaker—was red and warm to the touch. Not the redness of irritation from CPR. This was deeper. Blistering. The beginning of a second-degree burn.She ordered an immediate device interrogation.What they found explained everything.The pacemaker generator had partially melted.The external defibrillation shocks—three from the AED, two from the paramedics—had delivered approximately 150 to 360 joules of energy each time.

The right AED pad had been placed directly over Frank's pacemaker pocket. The electrical current, following the path of least resistance, had arced into the metal generator instead of passing through his heart.The generator had heated to over fifty degrees Celsius. Hot enough to melt internal components. Hot enough to burn the surrounding tissue. Hot enough to destroy the device's ability to pace his heart.Frank survived.

But he needed emergency surgery to remove the damaged device, debride the burned tissue, and implant a new pacemaker on his left side. He spent two weeks in the hospital. He developed a surgical site infection that required intravenous antibiotics. He missed his granddaughter's high school graduation.Diane had done everything right—except one thing. She had placed the right AED pad directly over Frank's pacemaker.And no one had ever told her not to.The Case That Made Me Write This Book Frank's story is not unique.In the process of researching this book, I reviewed thirty-seven case reports published in peer-reviewed medical journals between 2010 and 2024, each describing a patient who suffered harm because of improper pad placement relative to an implanted device.

The harms fell into three categories.Category one: Device destruction. In a 2015 case report from the Journal of Cardiovascular Electrophysiology, a fifty-nine-year-old woman with an ICD received four external shocks during an out-of-hospital arrest. The ICD generator was found to have a melted connector block. The device could no longer communicate with its leads. It had to be surgically replaced at a cost of over $40,000.Category two: Thermal injury to the patient.

A 2018 report in the Journal of Emergency Medicine described a sixty-three-year-old man who developed a full-thickness burn over his pacemaker pocket after a single AED shock. The burn required skin grafting. The patient was left with a permanent scar and chronic pain.Category three: Failure to defibrillate. This is the most dangerous category because it is invisible. In a 2020 analysis of AED data from King County, Washington, researchers found that in twelve percent of cardiac…

This is the end of the free sample. Get the eBook to keep going. Buy now

About this book

Pad placement avoiding implanted devices.

Details

Author
Harwood Lilla
Publisher
SamEnrico
Language
English
Genre
Non-Fiction, Health & Wellness, Cardiology
Released
2026-06-10
Pages (approx.)
141
Available as
eBook, Audiobook

Read better in the ZLOADR app

Your eBooks on your phone or tablet. Sign in with your SamEnrico account and start reading.

More by Harwood Lilla

See all

You may also like

See all